3.2.10 Fasteners

Molded Grating Fastener Options

Fasteners are essential components for securing molded FRP grating assemblies. They anchor panels to the supporting structure and, where required, connect adjacent panels to improve alignment and stability.

Proper fastening is particularly important in pedestrian-accessible areas, elevated installations, high-vibration environments, and any application where panel displacement could create a fall, trip, or equipment hazard.

Installation guidance: As a general best practice, each grating panel should be secured at all four corners. Additional fasteners may be required along intermediate supports, panel joints, perimeter edges, or high-load areas based on panel size, span, vibration, traffic, wind uplift, and the supporting structure.

The M-Type fastener is the preferred option for most standard molded grating installations. L-Type, C-Type, WLP-Type, G-Type, J-Type, and F-Type fasteners are available or may be specified for particular mesh patterns, support conditions, edge locations, and installation methods.

Available Fastener Types

Preferred Option

M-Type Fastener

The M-Type fastener is the standard hold-down option for most molded FRP grating installations. Its saddle-shaped upper plate bears across adjacent load bars while a bolt connects the plate to a lower anchor, support clip, or drilled structural member.

The M-Type provides dependable clamping pressure, broad compatibility, straightforward installation, and easy removal when access beneath the grating is required.

Common Applications
  • Standard molded grating
  • Industrial walkways
  • Platforms
  • Trench covers
  • Pedestrian flooring
Primary function: Secures a grating panel to the supporting structure.

L-Type Fastener

The L-Type fastener is used at panel edges and perimeter locations where an M-Type saddle cannot bear across two adjacent load bars. Its angled profile captures a single edge bar while the lower leg or bolt connects to the supporting structure.

This fastener provides a low-profile edge connection and is particularly useful where the grating terminates beside a wall, frame, curb, structural angle, or other obstruction.

Common Applications
  • Panel perimeters
  • Edge load bars
  • Wall interfaces
  • Framed openings
  • Restricted-access locations
Primary function: Secures an outside panel edge to the supporting structure.

C-Type Fastener

The C-Type fastener is primarily used to connect two adjacent molded grating panels. The opposing clip sections engage the load bars on each side of the panel joint and are tightened together with a bolt.

Connecting adjacent panels helps maintain alignment, reduces differential movement, and minimizes uneven panel edges at the joint. C-Type fasteners supplement panel-to-support hold-down fasteners but do not normally replace them.

Common Applications
  • Panel-to-panel joints
  • Large floor assemblies
  • Long walkways
  • Multi-panel platforms
  • Alignment control
Primary function: Joins two adjacent grating panels together.

WLP-Type Fastener

The WLP-Type fastener uses a broad, washer-like top plate that spans several closely spaced load bars. The wider bearing surface distributes clamping pressure over a larger portion of the grating than a conventional M-Type fastener.

It is particularly useful for minimesh, micromesh, closely spaced mesh, and some covered-grating configurations where the openings are too small for a standard saddle fastener or where a wider pressure-distribution plate is preferred.

Common Applications
  • Minimesh
  • Micromesh
  • ADA mesh
  • Covered grating
  • Small mesh openings
Primary function: Provides a wide-area hold-down connection for small-mesh and covered grating.

G-Type Fastener

The G-Type fastener is designed to grip the flange of the supporting steel member. Its lower component hooks beneath the flange while the upper plate bears on the grating and is tightened with a bolt.

This arrangement can eliminate the need to drill through the supporting steel, making it useful where field drilling is undesirable, restricted, or impractical.

Common Applications
  • Steel support flanges
  • No-drill installations
  • Retrofit projects
  • Removable flooring
  • Structural beams
Primary function: Clamps the grating to a support flange without drilling the support member.

J-Type Fastener

The J-Type fastener uses a hooked lower section that passes through the grating and engages beneath a support member, support flange, load bar, or other structural feature.

It is useful where access to the underside is limited or where a hook-style connection provides a more practical attachment than a drilled bolt or conventional lower clip.

Common Applications
  • Channel supports
  • Angle supports
  • Hook-under connections
  • Retrofit installations
  • Limited-access locations
Primary function: Hooks beneath a structural support to secure the grating from above.
F-Type image not currently available.

F-Type Fastener

The F-Type fastener is an internal friction-style fastener designed to sit down within the molded mesh opening. Its formed sides engage the tapered load bars and lock beneath the wider lower portion of the molded bars.

Because molded grating load bars generally taper from a narrower upper surface to a wider base, the fastener can develop a mechanical grip inside the mesh without requiring a broad saddle plate across the top.

This creates a low-profile connection with minimal hardware projecting above the walking surface. Compatibility depends on the specific mesh opening, panel depth, load-bar taper, and fastener dimensions.

Common Applications
  • Low-profile installations
  • Internal mesh fastening
  • Tapered molded bars
  • Restricted top clearance
  • Specialty grating assemblies
Primary function: Locks internally within the molded mesh by gripping the tapered load bars.

Fastener Selection Summary

Fastener Primary Function Typical Use Selection Considerations
M-Type Standard panel-to-support hold-down connection General molded grating, walkways, platforms, and trench covers Confirm compatibility with mesh size, panel depth, support type, and required bolt length
L-Type Secures a perimeter or outside load bar Panel edges, walls, frames, curbs, and restricted locations Used where a standard saddle cannot span adjacent load bars
C-Type Connects adjacent grating panels Multi-panel walkways, platforms, and floor assemblies Supplements, but does not replace, panel-to-support hold-downs
WLP-Type Wide-area hold-down for closely spaced mesh Minimesh, micromesh, ADA mesh, and covered grating Select the plate size and bolt arrangement for the specific mesh and panel depth
G-Type Clamps grating to a support flange without drilling Steel beams, channels, flange supports, and retrofit projects Confirm support-flange thickness, flange width, and lower-hook engagement
J-Type Hooks beneath a supporting structural member Angles, channels, beams, and limited-access installations Confirm hook geometry, support thickness, bolt length, and underside clearance
F-Type Locks internally within tapered molded load bars Low-profile and specialty molded-grating installations Compatibility depends on mesh opening, panel depth, bar taper, and the exact fastener geometry
Inspection and maintenance: Fasteners should be inspected periodically for looseness, corrosion, deformation, missing hardware, support movement, and panel wear. Inspection frequency should reflect the application, vibration, traffic, environmental exposure, and consequences of fastener failure. Replace damaged or significantly corroded hardware promptly.